Search results for "Slice selection"

showing 2 items of 2 documents

A new method to investigate brain stem structural-functional correlations using digital post-processing MRI - reliability in ischemic internuclear op…

2001

We investigated the reliability of a new digital post-processing magnetic resonance imaging (MRI) technique in ischemic brain stem lesions to identify relations of the lesion to anatomical brain stem structures. The target was a medial longitudinal fasciculus (MLF) lesion, which was evident from ipsilateral internuclear ophthalmoplegia (INO). Sixteen patients with acute unilateral INO and an isolated acute brain stem lesion in T2- and EPI-diffusion weighted MRI within 2 days after the onset of symptoms were studied. The MRI slice direction was parallel and perpendicular to a slice selection of a stereotactic anatomical atlas. The individual slices were normalized and projected in the digita…

AdultMalePathologymedicine.medical_specialtyInternuclear ophthalmoplegiaAnatomical structuresLesionImage Processing Computer-AssistedmedicineHumansAgedBrain MappingOphthalmoplegiamedicine.diagnostic_testbusiness.industryReproducibility of ResultsEye movementMagnetic resonance imagingAnatomyMiddle AgedMedial longitudinal fasciculusmedicine.diseaseMagnetic Resonance ImagingElectrooculographyElectrophysiologyNeurologySlice selectionFemaleNeurology (clinical)medicine.symptombusinessBrain StemEuropean Journal of Neurology
researchProduct

19F-MRT der Lungenventilation in Atemanhaltetechnik mittels SF6-Gas

2000

Breathhold 19 F-Magnetic Resonance Imaging of Lung Ventilation using SF 6 Gas. Objective: Development of a method to analyze lung ventilation by 19 F-magnetic resonance imaging (MRI) of inspired SF 6 gas during breathhold. Material and Methods: Measurements were performed with a Siemens Magnetom Vision 1.5T scanner using the conventional gradient overdrive. Coronal images of the lung were acquired using ultrafast gradient-echo pulse sequences with TR/TE/α = 1.4 ms/ 0.48 ms/40° without slice selection. With NEX = 200 averages and MA = 32 × 64 raw data matrix, the acquisition time was 9s/image. Higher spatial resolution of 4.7 × 6.3 × 15 mm 3 was obtained with a three-dimensional pulse sequen…

ScannerMaterials sciencebusiness.industryPulse (signal processing)Image qualityPulse sequenceNuclear magnetic resonanceSignal-to-noise ratio (imaging)Slice selectionRadiology Nuclear Medicine and imagingSignal averagingNuclear medicinebusinessImage resolutionRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct